Heat pipe
ΔPcap = 2σ/r
ΔPgravity = ρgL sin θ
ṁlimit = max(0, (ΔPcap − ΔPgravity)/Rflow)
Qphase = ṁ hfg
Water properties fixed near 60 °C: σ = 0.066 N/m, ρ = 983 kg/m³, hfg = 2.36 MJ/kg. Length 0.30 m; effective pore radius 25 µm; complete wetting. A deliberately simplified linear liquid-plus-vapour flow resistance of 4 × 10⁷ Pa/(kg/s) illustrates the capillary limit. Positive tilt puts the evaporator above the condenser. Removing the wick retains the same illustrative flow resistance to isolate the driving-pressure effect; it is not a quantitative thermosyphon model.
Selected as a thermal bridge in Moving heat. Below the return-flow limit, the assumed conductance (default 20 W/K, adjustable) relates transport to block-to-sink temperature difference. Above it, transport is capped and excess input warms the block unless removed by gas or radiation. This represents a return-flow limit rather than dynamically resolving dry-out. Heat flows only down the temperature gradient; for reverse flow, the tilt term reverses. This fixed 30 cm example is independent of the solid cross-section control, which is hidden when a heat pipe is selected. Wall conduction, boiling, sonic and entrainment limits, startup and freezing are omitted.
Heat transfer
Chot dThot/dt = Pin − Qtransfer
dHsink/dt = Qtransfer
d(Ehot + Hsink)/dt = Pin − vapour energy out
Qsolid = kA ΔT/L
Qpipe = sign(ΔT) min(Gpipe |ΔT|, Qlimit)
Qconv = hA ΔT
Qrad = εσSB A(Th⁴ − Tc⁴)
A lumped, uniform-temperature block starts at the surroundings temperature. Adjustable heat input (0–1000 W) enters over a fixed 100 cm² face; flux = power/0.01 m². Hot-block mass (1–5000 g) and material determine heat capacity C = m cₚ, with mass converted to kg. Fixed representative room-temperature cₚ values: copper 387, aluminium 900, silicon 703 and glass 837 J/(kg K). These are independent of the bridge material. Geometry and exposed area do not change with mass; this is a lumped thermal model, not a dimensioned block. Specific heat variation and phase changes are not modelled; high-temperature results are illustrative. The sink is a finite insulated body. All bridge, gas and radiative exchange enters it. For solid or melting sinks, no energy leaves the pair. Water and ethanol are vented boiling sinks: vapour leaves permanently and exports both sensible enthalpy and latent heat. The gas coefficient represents a lumped internal exchange path, not an external ambient loss. Radiation is an idealised mutual exchange coefficient controlled by the emissivity setting. The hot block is spatially uniform. By default the sink is a cube with 32–256 finite-volume layers (finer for low-conductivity materials) and one-dimensional heat conduction. Its side is (mass/density)^(1/3); the bridge delivers heat uniformly over a whole face through an ideal massless spreader. All other faces are insulated. The optional original model keeps the sink spatially uniform. The time trace is the mass-weighted mean of local sink temperatures, not a surface temperature. The profile shows heated surface, cell-centre temperatures and the insulated far surface. All incoming paths feed the same face. Gas and radiative effective areas retain their original values independently of cube size. Sink enthalpy includes sensible heat plus latent heat; liquid fraction rises from 0 to 100% at the model melting temperature, then temperature resumes rising. Wax is an illustrative paraffin: 55 °C, 200 kJ/kg latent heat, cp 2000 J/(kg K). Real waxes melt over a range and vary by grade. Lithium uses 180.5 °C and 432 kJ/kg latent heat, with constant cp 3580 J/(kg K) on both sides as a teaching approximation. Potassium uses 63.7 °C (rounded from NIST’s 2024 recommendation), latent heat 59.7 kJ/kg and constant cp 754 J/(kg K). These are teaching approximations, not design recommendations for reactive molten alkali metals. Water boils at 100 °C with cp 4186 J/(kg K) and latent heat 2256 kJ/kg; ethanol at 78.3 °C with cp 2450 J/(kg K) and latent heat approximately 837 kJ/kg. These fixed values assume a separately vented sink at 1 atmosphere, even if the bridge gas path is switched off by the ideal-vacuum control. Below-boiling evaporation, pressure dependence, vapour condensation/return, container heat capacity, chemistry and internal liquid convection are omitted. Cube layers can have different temperatures and melt fractions. Density and conductivity are held fixed; liquid geometry is idealised as retained in an insulated container. Boiling cells lose mass and vapour enthalpy locally; depleted cells are skipped without vapour-gap resistance. The surface and profile recede by whole cell widths as layers disappear. No container or spreader heat capacity is included. Liquid mass decreases by absorbed boiling heat divided by latent heat. At exhaustion, all sink paths stop; container and bridge heat storage are omitted. Sink traces end when dry. Only water and ethanol boil in this model; other materials retain their earlier sensible/melting behaviour. Melting and freezing follow the same idealised enthalpy curve without hysteresis. Copper, aluminium, silicon and glass use sensible heat only; their phase changes are not modelled. Pause freezes the thermal evolution; speed changes simulated time. Bridge heat storage, contact resistance and temperature-dependent properties are omitted. Separate heat-loss paths: adjustable solid cross-sectional area 0.001–200 cm² (default 1.5 cm² = 0.00015 m²); separate gas and radiation areas remain 0.01 m²; solid length adjustable 0.1–100 cm, default 5 cm; k = 400 (copper), 2000 (thermal-grade diamond), 90 (high-conductivity silicon nitride substrate), 612 (example copper–diamond composite), 15 (steel) or 0.04 (insulation) W/(m K). These are fixed illustrative values near room temperature; grade, microstructure, interfaces and temperature change real conductivity. Copper–diamond is a composite; the assumed value represents a published tungsten-coated-diamond example, not every copper–diamond material. Gas coefficient h = 8 W/(m² K). Ideal high vacuum sets the gas path to zero but leaves the solid bridge and radiation. Radiation exchanges between the blocks with an illustrative effective area and view factor 1. Temperatures in the radiation equation are kelvin. This is not a pump-down model.
Refrigeration
COPCarnot = Tc/(Th − Tc)
COPcooling = f × COPCarnot
Qhot = Qcold + W
COPheating = COPcooling + 1
Held reservoirs and idealised steady power balance. The selectable fraction f is an assumed fraction of Carnot cooling COP, not a compressor efficiency or a real-fluid cycle calculation. The circuit shows the usual vapour-compression stages, but does not calculate pressures or enthalpies. Kelvin temperatures are used in COP. All displayed heat flows and work inputs are powers.